Categories

Posts Tagged ‘ADR510’

Precision 1V reference

Thursday, November 29th, 2012

Need a precision reference to make sure your measurements are on the nose? Here is a simple breakout Dolabra designed for just that purpose. It's a ADR510 based battery powered 1V reference, with +0.35% tolerance and 70 ppm/C temperature stability. Via the forum.  

Tags: , ,
Posted in project logs, tools | 7 Comments »

Recent Comments

  • Drone: So these go for around $330 USD and NO published calibration procedure online or otherwise? Given what's inside - I don't think I'll be considering...
  • Pekka Akselin: This is ridiculous!? :-) We are back at 256(!) byte EPROMs that needed multiple, a handful, of voltages to run! :-(
  • KH: Let's try a back-of-envelope calc balancing energies. From MCP1700 datasheet, there are graphs for a 200mA load step. Estimate the energy shortfall as 12uJ. Say...
  • Daniel: It's been a week and my comment is still awaiting moderation. Apparently the CIA doesn't want their involvement known?
  • KH: Agree, so okay, I guess he must have learned from somewhere. 100nF and 1000uF is so far apart, that was jarring; it's more magic incantation...