Wavetek 907 repair, YIG oscillator teardown

Posted on Monday, August 4th, 2014 in repair, Teardowns by DP


Kerry Wong writes:

As I mentioned in my previous posting, there was an issue with my Wavetek 907 microwave frequency generator. While everything was fine during my initial testing, the frequency display is now stuck with an out-of-range display and the adjustable frequency range is limited to between around 6.9 Ghz to 7.9 Ghz (instead of all the way up to 11 Ghz). My initial suspicion was that the PTC heater inside the YIG-Gunn oscillator was malfunctioning. But as it turned out, it was something else.
Since initially my gut feeling told me that the YIG oscillator might be at fault, I thought I would at least try taking it apart to see if it was something trivial to fix. And even if it is beyond economical repair, it would at least be a pretty interesting teardown of the YIG oscillator itself.

This entry was posted on Monday, August 4th, 2014 at 5:00 pm and is filed under repair, Teardowns. You can follow any responses to this entry through the RSS 2.0 feed. You can skip to the end and leave a response. Pinging is currently not allowed.

One Response to “Wavetek 907 repair, YIG oscillator teardown”

  1. Peter says:

    You mean it’s supposed to go to 11?!

Leave a Reply

Notify me of followup comments via e-mail. You can also subscribe without commenting.

Recent Comments

  • Stephen Tinius: Thank you.
  • KH: Ah, the site sells boards, that's the reason. At least it's a XC6SL9 board that does not cost an arm and a leg, though it...
  • Max: While I understand this is more educational than practical in nature, I prefer my edutainment a lot more firmly grounded in economic reality. Sure, you...
  • KH: Using an alkaline coin cell down to 1.0V or under is a very bad idea anyway, unless you as the designer or manufacturer don't care...
  • KH: Farnell says TS1001 is no longer stocked. Not on RS. Digikey says it's obsolete. That said, there are a lot of nanoamp-class parts on sale...