Categories

Logic Sniffer back in stock at Seeed

Posted on Tuesday, July 10th, 2012 in logic analyzer by DP

The Logic Sniffer is back in stock at Seeed Studio. The Open Bench Logic Sniffer is an open source logic analyzer. It’s designed to support the SUMP logic analyzer software at the lowest possible cost.

Get a Logic Sniffer for $50, with free worldwide shipping.

This entry was posted on Tuesday, July 10th, 2012 at 9:00 pm and is filed under logic analyzer. You can follow any responses to this entry through the RSS 2.0 feed. You can skip to the end and leave a response. Pinging is currently not allowed.

9 Responses to “Logic Sniffer back in stock at Seeed”

  1. Chuckt says:

    I’m wondering if I can get by with a logic sniffer instead of an oscilloscope. Can someone please give me advice? Thank you.

    • Ian says:

      What kind of work are you doing? If you;re debugging digital circuits a logic analyzer can be much much more helpful than an o-scope. If you do analog stuff (very fast digital = analog too) then an o-scope is more useful. I personally don’t keep an oscope on my workbench because I use it so rarely.

    • Scott_D says:

      It really depends on what you are trying to do. The logic sniffer is a nice bit of kit if you want a logic level view of what is going on. But it won’t show you the analog picture of things. So you won’t be able to see, for example, noise on power rails or overshoot on digital pulses, etc. However, if what you need is something to show you what your digital signals are doing, then the logic sniffer is just the thing.
      It is much more useful if your normal project is a simple microcomputer based design. Looking at things like UART or SPI signals or PWM signals for example.

    • tinito says:

      The main difference, after the analog/digital, is about memory: oscilloscopes generally memorize what they can display on their screen, which is a very limited time, while logic analyzers can save much longer waveforms, e.g. a bunch of SPI transfers.
      You will never be able to debug SPI communication with only an oscilloscope without some magic.

  2. Udi says:

    With digital scopes being the norm rather than the exception, scopes can usually capture much more than what the screen shows, but the logic analyzer has two big advantages:
    Where a scope usually have 1 or 2 channels, logic analyzers (logic shrimp aside) have at least 8 or 16 channels.
    In addition, smart triggering and the use of mask&match logic can extend the length of time over which the logic analyzer can sample data, by capturing only important data points. A digital scope, on the other hand, once triggered, will continuously sample its analog input signals until its buffer is full.

    • tinito says:

      “much more” is not that much at least for non-expensive scopes: as an example, the tektronix DSO I use daily memorizes 2.5k points, which are 4 “screens”, not that much.
      BTW, the number of channels is another huge difference for sure.

      • Steve says:

        Depends on the non-expensive scope. The one I have by GW-INSTEK, does 2 Meg samples. Has come in handy a few times when I missed the proper trigger. The scrolling can sometimes be a pain and dumping 2 Meg samples to a CSV file takes forever; however the data is there.

  3. Waspinator says:

    Open logic sniffer probe cable still sold out :(

  4. Adrian says:

    Interesting that Ian doesn’t keep an oscilloscope on his bench – I always do, and I turn it on before the DVM (unless I need to measure resistance). I find a quick look at a signal or a power supply enormously helpful.

    I do also have some logic analysers and find the Saleae Logic particularly useful for things like SPI, but if I could only keep one instrument, it would be the scope – and an analog one at that. Modern digitals are great but often you don’t need more than real-time measurement.

    Keeping it on the workbench is important too : it’s one switch away from being used. It’s possible that if I had to get it out of a cupboard, I’d try to manage with the DVM instead (and miss a lot of useful information).

Leave a Reply

Notify me of followup comments via e-mail. You can also subscribe without commenting.

Recent Comments

  • Sjaak: I would add some more protection in the used trigger file (on the serverpilot site) then not using a standard name :) hopefully they use...
  • Pete Castagna: My friend Charlie who worked in synthesizers at a DOD type of place made a modification to this avalanche pulse generator that allowed him to...
  • Sam Catchpole: Yes please :D
  • Giovambattista Matera: another try
  • rumburack: jes